您的当前位置:首页BL660-F线路保护说明书

BL660-F线路保护说明书

2020-11-20 来源:爱问旅游网
BL660-F微机型线路保护测控装置使用说明书厦门佰力电力设备有限公司XIAMENBAILIELECTRICEQUIPMENTCO.,LTDBL660-F微机型线路保护测控装置技术说明书目录1.装置概述················································································································21.1应用范围·························································································································21.2功能特点·························································································································22.技术性能指标·······································································································42.1工作环境条件···············································································································42.2电气技术参数···············································································································43.装置原理结构·······································································································63.1软硬件平台····················································································································63.2结构与安装····················································································································74.功能介绍················································································································84.1保护功能·························································································································84.2监测功能·······················································································································114.3事件记录·······················································································································124.4故障录波·······················································································································135.参数设定说明·····································································································145.1系统参数·······················································································································145.2定值参数·······················································································································156.人机界面使用说明····························································································176.1信号指示灯··················································································································176.2小键盘···························································································································176.3液晶显示·······················································································································17附图一、交流回路原理图附图二、操作回路原理图附图三、装置端子排图装置概述1.1.装置概述1.1应用范围BL660-F是由双处理器构成的基于交流采样原理的数字式线路保护测控装1BL660-F微机型线路保护测控装置技术说明书置,主要适用于66KV及以下电压等级电力系统。它属于BL660-0中低压变电站成套保护测控装置系列中的一员。1.2功能特点本装置在软硬件及结构设计上采用了最新技术,保护功能完善,测量精度高,性能可靠,抗干扰能力强,可直接分散安装于开关柜上。该装置主要具备以下一些特点:☆硬件采用美国德州仪器公司(TEXASINSTRUMENTS)的高性能工业级DSP(数字信号处理)芯片+专用微处理器,双CPU结构,综合处理速度是常用16位微处理器的数十倍。☆整机全部采用贴片工业级芯片,集成度高,工作稳定可靠。☆采用国际最新铁电存储器存储重要数据,具有容量大、掉电不丢失数据、使用寿命无限、存取速度快等特点。☆软件采用C++高级语言及嵌入式汇编语言编程,模块化结构,便于升级维护。☆机箱为标准2U机箱,全封闭铝合金双层结构,美观大方。上层为CPU板,采用了四层印刷电路板,下层为交流模块板及操作回路板,上下层板间采用金属隔板隔离,抗干扰性能良好,结构紧凑可靠,安装调试方便。☆保护配置灵活齐全,各种保护功能均可通过控制字自由投退,具备远方在线修改定值功能。其中发电机保护、变压器主后备保护等具有复杂出口逻辑的装置具有软件可编程输出逻辑功能,大大增加了装置的适应能力。☆保护和监测的电流回路各自独立,既保证了测量的精度要求,又保证了保护的安全性、可靠性。☆装置的模拟量输入、开关量输入、电源输入及通讯接口部分采用了变压器隔离、光电隔离、TVS管保护等抗干扰措施,使得装置的抗干扰能力特别强。☆采用全中文简体汉字液晶显示界面,多层菜单、图标方式显示操作,显示信息丰富,薄膜小按键操作方便。显示屏幕采用128*64点阵蓝光高亮液晶模块,人机界面极为友好。☆装置可记录100次历史事件记录,记录内容详细。☆具有在线故障录波功能,可记录7次录波数据,每条记录包含各交流通道102BL660-F微机型线路保护测控装置技术说明书周波采样数据及开关输入量状态,装置屏幕可以显示录波数据及实时交流量波形图。☆装置提供谐波分析功能,可以提供三相电压电流的直到11次的奇次谐波数据。☆操作回路板设计新颖,采用最新的保持电流自适应设计,无需用户选择断路器跳合闸保持电流。☆装置具备完善的动静态自检功能,在线监视装置各部分工作状况,装置的两个CPU之间可以相互监视工作状况,当发现装置某部分工作不正常时自动发出告警信号,并闭锁相关保护出口,大大提高了装置工作可靠性。☆装置具有三级看门狗,外部硬件看门狗、CPU硬件定时器看门狗和软件看门狗,使装置在各重情况下均不会死机。☆装置具有强大的通信功能,用户可以选择RS485或CAN总线通讯方式。3BL660-F微机型线路保护测控装置技术说明书2.2.技术性能指标技术性能指标2.1工作环境条件2.1.1环境温度:2.1.2相对湿度:2.1.3大气压力:2.2电气技术参数2.2.1额定数据:2.2.2过载能力:2.2.3功率消耗:2.2.4精确测量范围:2.2.5测量精度:2.2.6保护整定范围:2.2.7保护动作时间:2.2.8开入回路:-20°C–60°C5%-95%86-106KPA交流电流:5A或1A交流电压:100V频率:50Hz电源:DC(或AC)220V(或110V),允许偏差±20%交流电流回路长期运行------2In10s-----------10In1s------------40In交流电压回路1.5Un连续工作直流回路不大于15W交流回路不大于0.5VA保护电流0.1In-20In测量电流0.1In-2In电压5V-200V保护电流<2%测量电流<0.2%保护电压<1%电流0.1In-20In级差0.01A电压5V-200V级差0.1V时间0s-100s级差0.01s在1.5倍定值下所有保护固有动作时间不大于35msDC(AC)220V,2mA(外部提供电源)或DC24V,1mA(装置内部提供电源)4BL660-F微机型线路保护测控装置技术说明书2.2.9开出接点:2.2.10绝缘电阻:2.2.11介质强度:2.2.12电磁兼容特性DC24V(线圈);触点可连续通过DC220V,5A电流装置所有电路与外壳之间的绝缘电阻在标准实验条件下,不小于100MΩ。装置所有电路与外壳的介质强度能耐受交流50Hz,电压2kV,历时1min试验,而无绝缘击穿或闪络现象。辐射电磁场干扰试验:符合国标GB/T14598.9的规定。快速瞬变干扰试验:符合国标GB/T14598.10的规定。脉冲群干扰试验:符合国标GB/T14598.13的规定。抗静电放电干扰试验:符合国标GB/T14598.14的规定。5BL660-F微机型线路保护测控装置技术说明书装置原理结构3.3.装置原理结构3.1软硬件平台装置采用本公司新一代保护软硬件通用平台。主芯片采用美国德州仪器公司(TEXASINSTRUMENTS)的高性能工业级DSP(数字信号处理)芯片TMS320LF2407A,该芯片处理速度为40MIPS,具有强大的数字信号处理能力;协处理器采用TI的超低功耗微处理器MSP430F149,该芯片为总线不出芯片的16位单片机,具有丰富的片上外设,有很强的控制处理能力。两个芯片通过高速同步串口(SPI)通讯,相互协作,共同完成装置的各项功能。装置硬件扩展了美国RAMTRON公司最新的大容量铁电存储器(FRAM),该存储器具有菲易失性、存储速度快、容量大等特点,用于保存保护定值、故障录波数据、历史事件记录等重要数据。模拟量变换由交流输入板完成。该板采用超小型CT、PT,完成大电流、电压到微处理器可接受的低电压的转换。装置软件是基于本公司最新的保护软件开发平台开发完成,该平台大部分代码采用C++高级语言编写,对于涉及到硬件最底层功能或特殊保护功能则采用汇编语言编写,这样既保证了软件的可读性,又满足了装置的实时性要求。保护装置硬件框图如图3.1.1。LPFRELAYLPFCoprocesso...MainProcessorSP...RELAY...USERINTERFACErCANBUSPOWERSUPPLY图3.1.1硬件框图6BL660-F微机型线路保护测控装置技术说明书3.2结构与安装装置采用2U标准铝机箱,嵌入式安装于屏(柜)上。内部结构采用抽屉方式,面板为整面板形式。电气部分采用上下两层结构,CPU板在中间隔离金属板上侧,操作回路板、开关电源固定在隔离板的下侧。交流量输入板固定在机箱底部。整个电路部分均由金属板隔离,大大提高了装置的抗干扰性能。当需要维修拆卸电路板时,首先切断装置供电电源,取掉机箱后部可插拔端子,将面框上下四个固定螺钉拆掉,然后在面框右侧背后解掉交流量输入电缆头,即可将装置整体电气部分(交流量输入板除外)一起抽出。机箱外形尺寸如图3.2.1,安装开孔尺寸如图3.2.2,安装示意图如图3.2.3。UNIT:mm16092297图3.2.1装置外形尺寸图89282图3.2.2安装开孔尺寸图图3.2.3安装示意图7BL660-F微机型线路保护测控装置技术说明书功能介绍4.4.功能介绍1保护功能4.4.14.1.1三段相间过流保护一段(速断)、二段(限时速断)和三段(过流)。每段保护跳闸时间分别整定,每段可选择带低电压元件闭锁或方向元件闭锁,每段可通过软压板自由投退。方向元件采用90°接线方式,即Uab对应Ic,Ubc对应Ia,Uca对应Ib,并遵循按相启动原则。装置考虑了当接近母线附近发生三相短路时会出现电压死区,因此增加了电压记忆功能,当电压大小满足装置测量精度时,保护逻辑采用实时电压,否则采用保护启动前的记忆电压。方向元件的灵敏角固定为45°,保护动作区为170°。低压闭锁投入电压不低》1PT断线信号方向闭锁投入&方向闭锁动作动作信号A相过流动作B相过流动作C相过流动作过流保护投入》1&延时动作出口信息显示及远传&4.1.2三相一次重合闸重合闸启动方式包括保护动作启动和开关偷跳启动两种,断路器位置及手合、手跳脉冲均取自装置内部操作回路,也可选择由外部开关量输入端子接入(定货时需注明)。重合闸在充电完成后自动投入,充电时间固定为15s。当同时满足以下三个条件时,装置开始充电:i.重合闸软压板投入;ii.重合闸硬压板投入;iii.断路器在合位;8BL660-F微机型线路保护测控装置技术说明书iv.无其它放电条件。当有以下任何事件发生时,重合闸立刻放电:i.手动或遥控分闸;ii.控制回路断线;iii.低周保护动作;重合闸可选检同期或检无压条件:对于检同期,在重合闸动作时间定值内,如果母线电压与线路电压相位差小于同期角度定值,则重合闸;对于检无压,如果所测的线路电压小于整定的无压定值,则重合闸。检同期的线路电压相别可以在定值中选择。检同期和检无压可通过软压板自由投退。同期检查&检同期投入无压检查&检无压投入保护动作出口不对应启动重合闸投入闭锁重合闸开关在合位&充电标志重合闸信号》1&延时合闸出口信息显示及远传4.1.3后加速当后加速投入,重合闸动作后3s内再次发生故障,二段、三段相间过流保护或零序过流、低电压保护动作,保护加速动作,超过3s后加速自动退出。后加速可通过软压板自由投退,加速时限可整定。9BL660-F微机型线路保护测控装置技术说明书II、III段或零序过流、低电压动作后加速投入重合闸3秒内&延时动作信号动作出口信息显示及远传4.1.4低周减载低周保护投入,当系统频率低于整定值,经过整定的延时间后,低周保护动作于跳闸;低周保护可通过软压板自由投退。如果低压闭锁投入时,当电压低于整定值时,闭锁低周保护。如果滑差闭锁投入时,当频率下降速度大于整定值时,闭锁低周保护。母线电压低&低电闭锁投入动作信号滑差闭锁投入&滑差大于定值系统频率低&低周保护投入&延时动作出口信息显示及远传4.1.5零序过流保护对于小接地系统,必需装设专门的零序CT来获得零序电流,这样可以获得较高的灵敏度。零序过流保护设一段时限,保护出口可以选择跳闸或只发告警信号。动作信号零序过流动作&零序过流投入延时跳闸动作出口告警信号信号10BL660-F微机型线路保护测控装置技术说明书4.1.6低压保护装置判断三个线电压值均小于整定值,经延时后跳闸。母线失压,三个线电压值均为0时,低压保护功能自动退出,低压保护可通过软压板自由投退。低电压保护动作低电压保护投入PT断线信号&延时动作信号动作出口信息显示及远传4.1.7PT断线报警装置接入电压为线电压,PT断线监测不设置可整定定值,由装置自动判别。判据如下:i.没有相间过流信号;ii.任一相电流大于0.2A,任一线电压小于2V或任意两相线电压之矢量和等于另一相线电压值;两个条件均满足,则判为PT断线。监测到PT断线后,装置自动发出告警信号,如相间过流的复合电压闭锁元件投入,则闭锁相间过流保护直至PT断线信号消失;PT断线信号也闭锁低电压保护。告警信号PT断线判据动作5s闭锁相间过流保护信息显示及远传2监测功能4.4.24.2.1交流量监测装置具有专门的测量电流回路输入,用于实现高精度的电量监测功能。装置通过交流采样计算可以提供电压、电流、三相有功、三相无功、三相视在功率、三相功率因数、四相限电度、频率等电气量。装置的功率采用两表法测量,因此必须正确接入测量电流的A相和C相,接入电压的相序也必须正确。上述电气量可以在装置的液晶屏幕上察看,也可以通过通讯总线上传。电压、保护电流及电度量显示方式为二次值,测量电流、功率则直接显示一次值。借助于DSP的高性能数据处理能力,装置提供了母线电压(Uab、Ubc、Uca)、保护电流(Ia、Ib、Ic)的谐波分析功能。装置提供每路交流量3、5、7、9、1111BL660-F微机型线路保护测控装置技术说明书次谐波的幅值大小,并可以柱状图形式直观显示各次谐波与基波的百分比值,两种显示模式可以自由切换。4.2.2非电量监测装置共具有14路非电量输入回路。输入回路可以选用多种供电方式:DC(或AC)220V(或110V),这几种方式需在外部输入端子提供相应电压;DC24V,在这种方式下,非电量输入回路的电源由装置内部DC/DC提供,外部端子只需接入无源接点即可。采用何种供电方式由用户在订货时提供。装置已在硬件和软件上充分考虑了非电量采集的去抖措施,没有特殊要求时装置可以分辨到10ms的脉冲宽度,分辨精度为2ms。一般情况下,装置的最后四路非电量已作内部定义,分别为:跳闸位置,合闸位置,手动跳闸,手动合闸。在采用装置内部操作回路时这四路信号已由内部操作回路板连线接入,因此这四路非电量端子不能再作其他用途。当保护装置采用外部的操作回路时,应当在这四路端子上接入相应的信号以保证装置动作逻辑的正确性。当需要采集转发外部脉冲电度表的脉冲计数时,为了适应电度表的输出需要,非电量输入应当选用DC24V供电方式。装置可以接入4路无源脉冲量,位于非电量输入的第7~10号端子,分别定义为反向有功电度、容性无供电度、正向有功电度、感性无功电度。3事件记录4.4.3装置可以记录共100条历史事件记录。记录包括过流保护动作、PT断线信号、非电量输入变位、控制回路断线、装置故障等各种类型事件,每条记录包含了事件发生的时标(精确到毫秒)、事件发生时的各种交流输入量值、各路非电量状态等信息。事件记录按照发生时间的先后顺序存储,当事件超过100条时,装置自动依次用最新的记录覆盖最旧的记录。在装置的液晶屏幕上可以察看各条事件记录内容,也可以通过通讯总线上传记录。12BL660-F微机型线路保护测控装置技术说明书4故障录波4.4.4装置可以存储7条故障录波信息。每条信息包含了录波的时标(精确到毫秒)、10个录波通道数据。故障录波由保护动作信号触发,记录的数据包括触发前5周波、触发后5周波,共约200ms的数据。录波的时标对应的是录波触发时刻的时间。对于BL660-F线路保护装置,10个录波通道分别对应于母线电压Uab、Ubc、Uca保护电流Ia、Ib、Ic、零序电流I0、零序电压U0、备用、非电量状态。对于交流量,录波数据格式为每周波记录24点,每条录波信息的每个通道包含240点数据;对于非电量,每点数据包括了14路非电量输入的状态,共记录240点数据。录波信息按照触发时间的先后顺序存储,当超过7条录波信息需要存储时,装置自动依次用最新的信息覆盖最旧的信息。在装置的液晶屏幕上可以察看各条故障录波信息内容(不包括非电量输入状态),也可以通过通讯总线上传录波数据。由于显示屏幕精度所限,液晶屏幕上的波形显示做了插值处理,所显示的幅值刻度仅做定性分析使用。作为故障录波中的一项特别功能,装置可以实时动态显示当前各录波通道的交流量波形,并可以调节显示幅值比例。类似于示波器的这项功能方便了现场交流量调试工作。图4.4.1直观的说明了故障录波数据在装置屏幕上显示格式。触发时刻显示区域共10个周波图4.4.1波形显示13BL660-F微机型线路保护测控装置技术说明书参数设定说明5.5.参数设定说明装置需要设定的参数有三种,一种是系统参数;一种是定值参数;再一种是通道参数。三种参数分别在“系统设定”、“定值设定”、“通道校准”三个菜单中设定。由于通道参数设定是对装置硬件交流通道的补偿,在装置出厂前就已设定完成,此处不再介绍。以下分别介绍系统参数、定值参数的设定。5.1系统参数装置在正式投运前,应正确输入系统参数以保证装置正常运行。5.1.1保护口令保护口令是保护装置的操作授权,进入“系统设定”、“定值设定”、“通道校准”、“开出传动”菜单均需要输入正确的保护口令。保护装置出厂设置的默认口令是0000,保护口令的设置范围为0000~9999。修改保护口令后应牢记修改后的值,否则将无法进入上述菜单进行操作。5.1.2通讯地址当装置采用RS485总线通讯方式时,必须输入正确的通信地址。通讯地址是总线通讯的装置标识。为保证通讯正常,总线上连接的所有装置的通讯地址必须保证唯一,它的设定范围是0000~0254。5.1.3波特率波特率是装置通讯速率参数,可以选择的通讯波特率有:1200bps、2400bps、4800bps、9600bps、19200bps、38400bps。同一总线上装置的通讯波特率设置必须保持一致。5.1.4CT变比CT变比指测量电流互感器的一次二次比值。变比的二次值装置已默认为5A(或1A),这里只需要用户输入变比的一次值。5.1.5PT变比PT变比指电压互感器的一次二次比值。变比的二次值装置已默认为100V,这里只需要用户输入变比的一次值。14BL660-F微机型线路保护测控装置技术说明书5.1.6保护类型用于选择保护装置接入的相别。当装置接入三相电压、三相电流时,选择“三相”;当装置仅接入两相电压、两相电流时,选择“两相”。当选择后者时,为了保证装置功率计算的正确,两相电压请接入Uab、Ubc。5.1.7事件显示用于选择事件记录的显示方式,可以选择“自动弹出”或“人工查询”。选择前者时,当装置显示运行监视菜单,发生事件时,记录会自动弹出;选择后者则不会。5.1.8滚屏延时可以设定运行监视菜单的自动滚屏延时时间。设定的范围为0000~9999s,当设定为0s时,装置退出自动滚屏显示模式,需要用户手动翻看。5.1.9时间、日期设定这里设定的是装置的系统时钟。显示方式为:年--月--日;时:分:秒。装置投运前,应正确输入该时钟。系统时钟设定后,一般不需要校准,装置失电时,时钟可以照常运走。5.2定值参数定值参数包含了保护功能的所需控制参数,请参照4.1节介绍正确整定。列表如下。序号123456789定值名称闭锁过流电压过流1段投退1段低压闭锁1段方向闭锁过流1段电流过流1段时间过流2段投退2段低压闭锁2段方向闭锁整定说明电压定值,整定范围:000.0V~199.9V软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”电流定值,整定范围:00.00A~99.99A时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”15对应保护功能相间过流的低压闭锁定值过流1段过流2段BL660-F微机型线路保护测控装置技术说明书1011121314151617181920212223242526272829303132333435363738过流2段电流过流2段时间过流3段投退3段低压闭锁3段方向闭锁过流3段电流过流3段时间零序过流投退零序过流控制零序过流电流零序过流时间重合闸投退重合闸时间重合闸检无压检无压电压重合闸检同期检同期合闸角同期线路电压后加速投退后加速时间低周减载投退低周减载频率低周减载时间低压闭锁低周闭锁低周电压滑差闭锁低周滑差定值低电压投退低电压电压电流定值,整定范围:00.00A~99.99A时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”软压板定值,可以选择“投入”、“退出”电流定值,整定范围:00.00A~99.99A时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”保护出口选择,可以选择“信号”、“跳闸”零序过流保护电流定值,整定范围:0.000A~9.999A时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”电压定值,整定范围:000.0V~199.9V软压板定值,可以选择“投入”、“退出”角度定值,整定范围:0000°~9999°相别选择,可以选择:Ua,Ub,Uc,Uab,Ubc,Uca软压板定值,可以选择“投入”、“退出”后加速时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”频率定值,整定范围:00.00~99.99Hz时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”电压定值,整定范围:000.0V~199.9V软压板定值,可以选择“投入”、“退出”频率变化定值,整定范围:00.00~99.99Hz/s软压板定值,可以选择“投入”、“退出”低电压保护电压定值,整定范围:000.0V~199.9V低周减载重合闸过流3段16BL660-F微机型线路保护测控装置技术说明书3940低电压时间接地选线投退时间定值,整定范围:00.00s~99.99s软压板定值,可以选择“投入”、“退出”小电流接地选线人机界面使用说明6.6.人机界面使用说明装置的人机界面分为三个部分,一为信号指示灯;二为轻触小键盘;三为大屏幕汉字液晶显示。三部分分工合作,互为补充。Uab:100.1VIap:03.38AUbc:098.9VIbp:03.24AUca:099.7VIcp:01.69AST200F电流电压 01/11确认复归运行动作告警通讯图6.1.1面板布置图6.1信号指示灯装置面板右上方具有四个指示灯,分别指示为“运行”、“动作”、“告警”、“通讯”。正常运行时,“运行”灯点亮为绿色,表示保护装置工作正常;当保护动作时,“动作”灯点亮为红色;装置有告警信号时,“告警”灯点亮为红色;“动作”、“告警”灯具有自保持功能,一旦该灯点亮,除非按下“复归”键,否则该信号灯保持常亮;“通讯”灯指示装置通讯状况,当装置发送或接收数据时,该灯保持闪烁。6.2小键盘装置面板右下方有“确认”、“上”、“下”、“左”、“右”、“复归”六个键。“复归”键用于复归保护动作、告警信号灯。“确认”、“上”、“下”、“左”、“右”五个键与汉字液晶显示配合使用。“确认”键用于进入子菜单或退出当前菜单;“上”、“下”、“左”、“右”用于移动光标,“上”、“下”键也可以用于修改参数数值。显示6.3液晶液晶显示装置前面板靠左位置装有一块128*64点阵液晶模块,可以显示图形、简体17BL660-F微机型线路保护测控装置技术说明书汉字、数值等信息。装置采用多级菜单显示操作方式,菜单目录结构如图6.3.1所示。初始画面主菜单运行监视察看实时运行量系统设定输入口令定值设定输入口令通道校准整定定值参数设定系统参数开出传动输入口令设定通道参数事件记录输入口令传动出口信号继电器故障录波察看事件记录示波器察看故障波形图6.3.1菜单结构图6.3.1运行监视菜单18BL660-F微机型线路保护测控装置技术说明书装置刚上电时,首先显示LOGO,然后自动进入运行监视菜单。该菜单显示保护装置的实时监测交流量、非电量状态、谐波数据。屏幕最下一行显示保护软件型号、当前屏显示的内容提示、重合闸充电状态、显示的屏号。特别的提示是,通过“左”、“右”键可以切换谐波数据的显示方式(数值显示或柱状图显示)。Uab:100.1VIap:05.04AUbc:099.7VIbp:05.01AUca:100.0VIcp:05.04ABL660-F电流电压 01/11图6.3.2运行监视菜单示意图6.3.2主菜单在运行监视菜单中,按下“确认”键即进入主菜单。主菜单共七项选择:运行监视,系统设定,定值设定,通道校准,开出传动,事件记录,故障录波。全部采用直观的图标显示。通过“上”、“下”、“左”、“右”键选择要进入的菜单,按下“确认键”,即进入光标所在项子菜单。屏幕的最下方为滚动条。运行监视01/07图6.3.3主菜单示意图6.3.3系统设定菜单进入系统设定需要输入保护口令。通过“上”、“下”、“左”、“右”键,输入正确的口令,按下“确认”键即进入系统设定菜单。通过“上”、“下”键选择欲修改的参数,光标所在位置为反显色。选中后,按“左”或“右”键移动光标进入修改状态,通过“上”、“下”键可以进行修改数值。修改完该参数后,通过“左”或“右”键退出修改状态。修改完后,按“确认”键保存参数并退出该菜单,回到主菜单。19BL660-F微机型线路保护测控装置技术说明书通讯地址:波特率:CT变比:02/09000019200bps0100A/5A图6.3.4系统设定菜单示意图6.3.4定值设定菜单进入定值设定需要输入保护口令。通过“上”、“下”、“左”、“右”键,输入正确的口令,按下“确认”键即进入定值设定菜单。通过“上”、“下”键选择欲修改的定值,光标所在位置为反显色。选中后,按“左”或“右”键移动光标进入修改状态,通过“上”、“下”键可以进行修改。修改完该定值后,通过“左”或“右”键退出修改状态。当所有修改操作完成后,按一次“确认”键,可以保存修改过的定值并退出修改定值项,回到主菜单。过流I段投退过流I段电流过流I段时间01/40图6.3.5定值设定菜单示意图6.3.5通道校准菜单为了消除由于硬件不一致而引起的各交流输入通道的差别,特设通道校准,通过软件来调整平衡。进入通道校准需要输入保护口令。通过“上”、“下”、“左”、“右”键,输入正确的口令,按下“确认”键即进入通道校准菜单。屏幕中每一行的第一栏数字为该通道系数,第二栏数字为调整后该通道的显示值,通过修改通道系数,使得显示值与外加交流量基本一致。通过“上”、“下”、“左”、“右”键,可以完成通道系数的修改,修改完后,按“确认”键保存系数并退出该菜单,回到主菜单。投入24.50A00.10S20BL660-F微机型线路保护测控装置技术说明书UabUbcUca01/131.4351.4671.443100.01V100.03V100.00V图6.3.6通道校准菜单示意图6.3.6开出传动菜单进入开出传动需要输入保护口令。通过“上”、“下”、“左”、“右”键,输入正确的口令,按下“确认”键即进入开出传动菜单。可以通过“上”、“下”键选择欲传动的继电器,按“左”、“右”可以闭合所选择的继电器,按“复归”键复归已闭合的继电器,按“确认”键返回主菜单。继电器1:继电器2:继电器3:01/08图6.3.7开出传动菜单示意图6.3.7事件记录菜单进入事件记录菜单,如图6.3.8所示。通过“上”、“下”键翻看各条记录。对于需要记录动作参数的事件,如过流2段保护动作等,按一次“左”或“右”键即可显示该事件发生时的各交流量。按“确认”键返回主菜单。过流1段动作2002年08月12日11时32分45秒0878毫秒15/00图6.3.8事件记录菜单示意图21BL660-F微机型线路保护测控装置技术说明书6.3.8故障录波菜单进入故障录波菜单后,先通过“上”、“下”键选择示波器功能或各条录波记录,如图6.3.9所示。录波数据32002年08月12日11时32分45秒0878毫秒04/08图6.3.9故障录波菜单示意图选定记录后,按“确认”键进入波形显示菜单。在该菜单中,首先通过“左”、“右”键移动光标选择“上”、“下”键的功能。当光标在屏幕左上角时,“上”、“下”键的功能是放大、缩小显示比例;当光标在屏幕左下角第一格时,“上”、“下”键的功能是左右平移X坐标,每按一次坐标平移24个采样点;当光标在屏幕左下角第二格时,“上”、“下”键的功能是切换录波通道。按“确认”键返回主菜单。002V/div048Uab1图6.3.10波形显示菜单示意图特别说明:保护装置正常运行时,液晶屏幕显示运行监视菜单,动态刷新各显示量。当系统参数中“事件显示”设置为“自动弹出”时,当有保护事件发生,屏幕自动切换到事件记录菜单,显示当前最新发生的一条事件。另外,当保护进入“系统设定”、“定值设定”、“通道校准”、“开出传动”菜单时,为了保证操作正常,保护功能将自动退出。退出上述菜单后,保护功能自动重新投入。22

因篇幅问题不能全部显示,请点此查看更多更全内容